Skip to main content

Covered Tasks Reference Table

IMPORTANT

Looking for Pipeline Performance Profile Sheets? Find them in the Reports section after signing into your NCCER Account.

Covered Task Number Covered Task Title – Qualification Description Craft Title
AOCCC-17 Abnormal Operating Conditions – Control Center All
AOCFG-17 Abnormal Operating Conditions Field and Gas All
CT0021 Measure Soil Resistivity Pipeline Corrosion
CT0031 Inspect and Monitor Galvanic Ground Beds/Anodes Pipeline Corrosion
CT0091 Troubleshoot and Repair In-Service Cathodic Protection System Pipeline Corrosion, Pipeline Electrical & Instrumentation
CT0121 Collect Sample for Internal Corrosion Monitoring Pipeline Corrosion
CT0441 Compressor Startup and Shutdown (Field Operations) Pipeline Operations
CT0451 Pump Startup and Shutdown (Field Operations) Pipeline Operations
CT0461 Compressor Preventive Maintenance Pipeline Maintenance
CT0461-ISOPU Isolate and Purge a Compressor Unit (Field) Pipeline Maintenance
CT0471 Inspect, Test, and Maintain Reciprocating Compressor Pipeline Maintenance, Pipeline Mechanical
CT0481 Inspect, Test, and Maintain Centrifugal Compressor Pipeline Maintenance, Pipeline Mechanical
CT0491 Inspect, Test, and Maintain Rotary Compressor Pipeline Maintenance, Pipeline Mechanical
CT0501 Pump Preventive Maintenance Pipeline Maintenance
CT0511 Inspect, Test, and Maintain Centrifugal Pump Pipeline Maintenance, Pipeline Mechanical
CT0521 Inspect, Test, and Maintain Reciprocating Pump Pipeline Maintenance, Pipeline Mechanical
CT0531 Inspect, Test, and Maintain Rotary Pump Pipeline Maintenance, Pipeline Mechanical
CT0541 Inspect, Test, and Maintain Screw Pump Pipeline Maintenance, Pipeline Mechanical
CT0591 Leak Test at Operating Pressure Pipeline Maintenance, Pipeline Operations
CT0601 Perform NDT: Radiographic Testing Pipeline Maintenance
CT0611 Perform NDT: Liquid Penetrant Testing Pipeline Maintenance
CT0621 Perform NDT: Magnetic Particle Testing Pipeline Maintenance
CT0631 Perform NDT: Ultrasonic Testing Pipeline Maintenance
CT0661 Perform API 653 Inspection of Out-of-service Breakout Tanks Pipeline Maintenance
CT0671 Join Plastic Pipe: Solvent Cement Pipeline Maintenance
CT0681 Join Plastic Pipe: Stab Fittings Pipeline Maintenance
CT0691 Joining of Pipe: Nonbottom-Out Compression Couplings (2 inches and under) Pipeline Maintenance
CT0701 Joining of Pipe: Bottom-Out Compression Couplings (2 inches and under) Pipeline Maintenance
CT0711 Joining of Pipe: Compression Couplings (over 2 inches) Pipeline Maintenance
CT0741 Joining of Pipe: Brazing or Soldering Pipeline Maintenance
CT0751 Join Plastic Pipe by Butt Heat Fusion: Manual Pipeline Maintenance
CT0761 Join Plastic Pipe by Butt Heat Fusion: Hydraulic Machine Pipeline Maintenance
CT0771 Join Plastic Pipe: Sidewall Heat Fusion Pipeline Maintenance
CT0771-0781 Join Plastic Pipe: Sidewall Electrofusion Pipeline Maintenance
CT0781 Join Plastic Pipe: Electrofusion Pipeline Maintenance
CT0791 Join Plastic Pipe: Socket Heat Fusion Pipeline Maintenance
CT0861 Installation of Steel Pipe in an Open Trench Pipeline Maintenance
CT0871 Installation of Steel Pipe in a Bore Pipeline Maintenance
CT0881 Installation of Steel Pipe by Plowing/Pull-In Pipeline Maintenance
CT0891 Field Bending of Steel Pipe Pipeline Maintenance
CT0901 Installation of Plastic Pipe in a Ditch Pipeline Maintenance
CT0911 Installation of Plastic Pipe in a Bore Pipeline Maintenance
CT0921 Installation of Plastic Pipe Plowing/Pull-In Pipeline Maintenance
CT0931 Installation of Plastic Pipe by Plowing/Planting Pipeline Maintenance
CT0941 Install Tracer Wire Pipeline Maintenance
CT0951 Installation of Pipe Above Ground Pipeline Maintenance
CT0971 Install and Maintain Casing Spacers, Vents, and Seals Pipeline Maintenance
CT1011 External Coating Application and Repair: Wrapped Pipeline Corrosion
CT1071 Repair Steel Pipe by Grinding Pipeline Maintenance
CT1101 Tapping a Pipeline with a Self-tapping Tee (Built-in Cutter) Pipeline Maintenance
CT1141 Squeeze Off Plastic Pipe Pipeline Maintenance, Pipeline Mechanical
CT1151 Squeeze Off Steel Pipe Pipeline Maintenance, Pipeline Mechanical
CT1161 Install Customer Meters and Regulators: Residential and Small Commercial Pipeline Maintenance, Pipeline Mechanical
CT1171 Install Customer Meters and Regulators: Large Commercial and Industrial Pipeline Maintenance, Pipeline Mechanical
CT1201 Temporary Isolation of Service Lines and Service Discontinuance Pipeline Maintenance, Pipeline Operations
CT1231 Perform Inside Gas Leak Investigation Pipeline Maintenance
CT1241 Perform Outside Gas Leak Investigation Pipeline Maintenance
CT1281 Mobile Gas Leakage Survey: Optical Methane Pipeline Maintenance
CT1411-ACCA Perform AC Current Attenuation (ACCA or PCM) Survey Pipeline Corrosion
CT1411-ACVG Perform Alternating Current Voltage Gradient (ACVG) Survey Pipeline Corrosion
CT1411-DCVG Indirect Inspection – Perform Direct Current Voltage Gradient (DCVG) Survey Pipeline Corrosion
CT1631 Launching and/or Receiving Internal Devices (Pigs) for Lines Out of Service Pipeline Maintenance
CT1671 Inspect and Maintain a Pipeline Heater Pipeline Maintenance, Pipeline Mechanical
CT1681 Inspect, Test, and Maintain Liquid Knockout (Dehydration) System Pipeline Maintenance, Pipeline Mechanical
CT1691 Inspect, Test, and Maintain Glycol Dehydration System Pipeline Maintenance, Pipeline Mechanical
CT1701 Inspect, Test, and Maintain Mole Sieve Dehydration System Pipeline Maintenance, Pipeline Mechanical
CT1_1-17 Measure Structure-to-Soil Potentials Pipeline Corrosion Control L2
CT1_2-17 Conduct Close Interval Survey Pipeline Corrosion Control L2
CT1_3-17 Test and Detect Interference Pipeline Corrosion Control L2
CT1_4-17 Inspect and Perform Electrical Test of Bonds Pipeline Corrosion Control L2
CT1_5-17 Inspect and Test Electrical Isolation Pipeline Corrosion Control L2
CT2_1-17 Verify Test Lead Continuity Pipeline Corrosion Control L1
CT2_2-17 Repair Damaged Test Leads Pipeline Corrosion Control L1
CT2_3-17 Install Test Leads by Non-Exothermic Welding Methods Pipeline Corrosion Control L1
CT2_4-17 Install Test Leads by Exothermic Welding Methods Pipeline Corrosion Control L1
CT3_0-17 Obtain a Voltage and Current Output Reading from a Rectifier to Verify Proper Performance Pipeline Corrosion Control L1
CT4_1-17 Troubleshoot Rectifier Pipeline Corrosion Control L1
CT4_2-17 Repair or Replace Defective Rectifier Components Pipeline Corrosion Control L1
CT4_3-17 Adjustment of Rectifier Pipeline Corrosion Control L1
CT5_1-17 Examine for Mechanical Damage on Buried or Submerged Pipe Pipeline Corrosion Control L1
CT5_2-17 Examine for External Corrosion on Buried or Submerged Pipe Pipeline Corrosion Control L1
CT5_3-17 Inspect the Condition of External Coating on Buried or Submerged Pipe Pipeline Corrosion Control L1
CT7_1-17 Visual Inspection of Atmospheric Coatings Pipeline Corrosion Control L1
CT7_2-17 Prepare Surface for Coating Using Hand and Power Tools Pipeline Corrosion Control L1
CT7_3-17 Prepare Surface for Coating by Abrasive Water Blasting Pipeline Corrosion Control L1
CT7_4-17 Prepare Surface for Coating by Abrasive Blasting Media Other Than Water Pipeline Corrosion Control L1
CT7_5-17 Apply Coating Using Hand Application Methods Pipeline Corrosion Control L1
CT7_6-17 Apply Coating Using Spray Application Pipeline Corrosion Control L1
CT7_7-17 Perform Coating Inspection Pipeline Corrosion Control L1
CT8_1-17 Measure Pit Depth with Pit Gauge Pipeline Corrosion Control L1
CT8_2-17 Measure Wall Thickness with Ultrasonic Meter Pipeline Corrosion Control L2
CT8_3-17 Measure Corroded Area Pipeline Corrosion Control L2
CT9_1-17 Install Bonds Pipeline Corrosion Control L2
CT9_2-17 Install Galvanic Anodes Pipeline Corrosion Control L2
CT9_3-17 Install Rectifiers Pipeline Corrosion Control L2
CT9_4-17 Install Impressed Current Groundbeds Pipeline Corrosion Control L2
CT9_5-17 Repair Shorted Casings Pipeline Corrosion Control L2
CT9_6-17 Install Electrical Insulating Device Pipeline Corrosion Control L2
CT10_1-17 Insert and Remove Coupons Pipeline Corrosion Control L2
CT10_2-17 Monitor Probes (Online) Pipeline Corrosion Control L2
CT11_0-17 Monitoring and Controlling the Injection Rate of the Corrosion Inhibitor Pipeline Corrosion Control L2
CT12_0-17 Visually Inspect Internal Pipe Surface Pipeline Corrosion Control L1
CT14_1-17 Locate Line Pipeline Maintenance L3
CT14_2-17 Install, Inspect, and Maintain Permanent Marker Pipeline Maintenance L3
CT14_5-17 Install, Inspect, and Maintain Temporary Marker Pipeline Maintenance L3
CT15_1-17 Visually Inspect Surface Conditions of Right-of-Way Pipeline Maintenance L2
CT16_1-17 Inspect Navigable Waterway Crossing Pipeline Maintenance L2
CT19_1-17 Valve Body Winterization or Corrosion Inhibition Pipeline Mechanical L2
CT19_2-17 Valve Lubrication Pipeline Mechanical L2
CT19_3-17 Valve Seat Sealing Pipeline Mechanical L2
CT19_4-17 Valve Stem Packing Maintenance Pipeline Mechanical L2
CT19_5-17 Adjust Actuator/Operator, Electric Pipeline Mechanical L2
CT19_6-17 Adjust Actuator/Operator, Pneumatic Pipeline Mechanical L2
CT19_7-17 Adjust Actuator/Operator, Hydraulic Pipeline Mechanical L2
CT20_0-17 Inspect Main-Line Valves Pipeline Mechanical L3
CT21_1-17 Repair Valve Actuator/Operator, Pneumatic Pipeline Mechanical L3
CT21_2-17 Disassemble and Reassemble Valves Pipeline Mechanical L3
CT21_3-17 Internal Inspection of Valves and Their Components Pipeline Mechanical L3
CT21_4-17 Repair Valve Actuator/Operator, Hydraulic Pipeline Mechanical L3
CT21_5-17 Repair Valve Actuator/Operator, Electric Pipeline Mechanical L3
CT22_1-17 Inspect Tank Pressure / Vacuum Breakers Pipeline Mechanical L3
CT22_2-17 Inspect, Test, and Calibrate HVL Tank Pressure Relief Valves Pipeline Mechanical L3
CT23_1-17 Maintain and Repair Relief Valves Pipeline Mechanical L3
CT23_2-17 Inspect, Test, and Calibrate Relief Valves Pipeline Mechanical L3
CT24_1-17 Maintain and Repair Pressure Limiting Devices Pipeline Mechanical L3
CT24_2-17 Inspect, Test, and Calibrate Pressure Limiting Devices Pipeline Mechanical L3
CT25_1-17 Inspect, Test, and Calibrate Pressure Switches Pipeline Electrical and Instrumentation L2
CT25_2-17 Inspect, Test, and Calibrate Pressure Transmitters Pipeline Electrical and Instrumentation L2
CT26_0-17 Verify or Set Protection Parameters for Programmable Controllers and/or Other Instrumentation Control Loops Pipeline Electrical and Instrumentation L2
CT27_1-17 Routine Inspection of Breakout Tanks (API 653 Monthly or DOT Annual) Pipeline Maintenance L2
CT27_2 Perform API 653 Inspection of In-service Breakout Tanks Pipeline Maintenance L2
CT27_3 Perform API 510 Inspection of In-service Pressure Vessels Pipeline Maintenance L2
CT28_0-17 Provide Security for Pipeline Facilities Pipeline Maintenance L2
CT29_1-17 Launching In-Line Inspection Devices Pipeline Maintenance L3
CT29_2-17 Receiving In-Line Inspection Devices Pipeline Maintenance L3
CT30_0-17 Test Overfill Protective Devices Pipeline Electrical and Instrumentation L2
CT31_0-17 Inspect and Calibrate Overfill Protective Devices (Liquid) Pipeline Electrical and Instrumentation L2
CT32_0-17 Observation of Excavation Activities Pipeline Maintenance L2
CT33_1-17 Determine Allowable Line Pressure in Section of Pipe to be Moved Pipeline Maintenance L3
CT33_2-17 Preparation for Movement Activities Pipeline Maintenance L3
CT33_3-17 Moving In-Service Pipeline Pipeline Maintenance L3
CT35 Measure Clearance from Existing Pipe to Foreign Structures Pipeline Maintenance
CT34_0-17 Inspect Existing Pipe Following Movement Pipeline Maintenance L2
CT36_1-17 Safe Disconnect of Pipeline Facilities Pipeline Maintenance L3
CT36_2-17 Purging of Pipeline Facilities Pipeline Maintenance L3
CT36_3-17 Sealing a Disconnected Portion of Pipeline Pipeline Maintenance L3
CT37_0-17 Install or Repair Support Structures on Existing Aboveground Components Pipeline Maintenance L2
CT38_1-17 Visually Inspect Pipe and Pipe Components Prior to Installation Pipeline Maintenance L2
CT38_3-17 Visually Inspect that Welds Meet DOT Requirements Pipeline Maintenance L3
CT39_0-17 Backfilling a Trench Following Maintenance Pipeline Maintenance L2
CT40_1-17 Fit Full Encirclement Welded Split Sleeve Pipeline Maintenance L3
CT40_3-17 Apply Composite Sleeve Pipeline Maintenance L3
CT40_4-17 Install Mechanical Bolt-On Split Repair Sleeve Pipeline Maintenance L3
CT40_5-17 Install Weldable Compression Coupling Pipeline Maintenance L3
CT40_6-17 Install and Remove Plugging Machine Pipeline Maintenance L3
CT40_7-17 Installing a Tap 2 Inches and Under on a Pipeline System Pipeline Maintenance L3
CT40_8-17 Installing a Tap Larger Than 2 Inches on a Pipeline System Pipeline Maintenance L3
CT40_9-17 Install and Remove Completion Plug on Pipelines Larger than 2 Inches Pipeline Maintenance L3
CT41_0-17 Conduct Pressure Test Pipeline Maintenance L3
CT42_7-17 Welding Pipeline Maintenance L3
CT44_3-17 Inspect, Test, and Maintain Flow Computer for Hazardous Liquid Leak Detection Pipeline Electrical and Instrumentation L2
CT44_4-17 Inspection, Testing, and Corrective and Preventative Maintenance of Tank Gauging for Hazardous Liquid Leak Detection Pipeline Electrical and Instrumentation L2
CT44_5-17 Prove Flow Meters for Hazardous Liquid Leak Detection Pipeline Electrical and Instrumentation L2
CT44_6-17 Maintain Flow Meters for Hazardous Liquid Leak Detection Pipeline Electrical and Instrumentation L2
CT44_7-17 Inspect, Test, and Maintain Gravitometers/Densitometers for Hazardous Liquid Leak Detection Pipeline Electrical and Instrumentation L2
CT44_8-17 Inspect, Test, and Maintain Temperature Transmitters for Hazardous Liquid Leak Detection Pipeline Electrical and Instrumentation L2
CT50_0-17 Purge Gas from a Pipeline Pipeline Operations L2
CT51_0-17 Purge Air from a Gas Pipeline Pipeline Operations L2
CT52_1-17 Conduct Vegetation Survey Pipeline Maintenance L2
CT52_2-17 Conduct a Leak Survey with a CGD Pipeline Maintenance L2
CT52_3-17 Conduct a Leak Survey with a Flame Ionization Unit Pipeline Maintenance L2
CT54_0-17 Test Remotely Controlled Shutdown Devices Pipeline Operations L2
CT55_0-17 Maintain Fixed Gas Detection Equipment Pipeline Electrical and Instrumentation L2
CT56_0-17 Perform Incremental Pressure Increases to Uprate the MAOP Pipeline Operations L2
CT57_0-17 Operate Odorant Equipment Pipeline Operations L2
CT58_0-17 Monitor Odorant Level Pipeline Operations L2
CT59_0-17 Vault Maintenance Pipeline Maintenance L2
CT63_1-17 Start-Up of a Liquid Pipeline (Field) Pipeline Operations L2
CT63_2-17 Shutdown of a Liquid Pipeline (Field) Pipeline Operations L2
CT63_3-17 Monitor Pressures, Flows, Communications, and Line Integrity and Maintain Them Within Allowable Limits on a Liquid Pipeline System (Field) Pipeline Operations L2
CT63_4-17 Locally Operate Valves on a Liquid Pipeline System (Field) Pipeline Operations L2
CT64_1-17 Start-Up of a Liquid Pipeline (Control Center) Pipeline Operations L2
CT64_2-17 Shutdown of a Liquid Pipeline (Control Center) Pipeline Operations L2
CT64_3-17 Monitor Pressures, Flows, Communications, and Line Integrity and Maintain Them Within Allowable Limits on a Liquid Pipeline System (Control Center) Pipeline Operations L2
CT64_4-17 Remotely Operate Valves on a Liquid Pipeline System Pipeline Operations L2
CT65_1-17 Start-Up of a Gas Pipeline Pipeline Operations L2
CT65_2-17 Shutdown of a Gas Pipeline Pipeline Operations L2
CT65_3-17 Monitor Pressures, Flows, Communications and Line Integrity and Maintain Them Within Allowable Limits (Gas) Pipeline Operations L2
CT65_4-17 Manually or Remotely Open or Close Valves or Other Equipment Pipeline Operations L2
CTCC-17 Cold Cutting Pipeline Maintenance L2
CTFB-17 Flange Bolting Pipeline Maintenance L2
CTMP-17 Mud Plugging Pipeline Maintenance L2
CTTB-17 Tubing Pipeline Maintenance L2
CTTP-17 Threaded Pipe Fabrication Pipeline Maintenance L2
CTAIR Operate Air Movers Pipeline Maintenance L2
CTBUFF Repair Steel Pipe by Buffing Pipeline Maintenance
CTCASE-INSTL Installation of Underground Casing Pipeline Maintenance
CTCLOSE Operate and Maintain Closure Devices Pipeline Maintenance
CTFP Freeze Plugs Pipeline Maintenance
CTHYDVAC Hydrovac Operations Pipeline Maintenance
CTRC Removal of Casing (Hot or Cold Cut) Pipeline Maintenance
CTRMLD Conduct a Leak Survey Using a Remote Methane Leak Detector Pipeline Maintenance
CTTANK Tank Repair Pipeline Maintenance